810 research outputs found

    Reliability of a Barre-Mounted Dynamometer-Stabilizing Device in Measuring Dance-Specific Muscle Performance

    Get PDF
    BACKGROUND: Hand-held dynamometry is considered an efficient, effective, and portable means of objectively measuring lower extremity strength; however, it has yet to be studied specific to dance-relevant muscle performance. Also, dynamometry is often criticized for variability in results based on tester strength and sex. Use of an external stabilizing device has been suggested to minimize differences in outcomes between male and female testers by reducing variability associated with tester strength limitations. Therefore, this study used a barre-mounted, portable dynamometer stabilizing device to improve consistency of results among different testers for assessing hip and lower extremity muscle performance in dance-relevant positions. OBJECTIVE: To assess the intra and inter-rater reliability of a barre-mounted dynamometer stabilizing device in measuring muscle performance in common dance maneuvers. METHODS: Two testers assessed muscle performance of three common dance maneuvers-—développé en avant, à la secondé, and arabesque-—on 11 pre-professional and professional dancers on two separate occasions to establish intra- and inter-rater reliability of the barre-mounted dynamometer stabilizing device. RESULTS: Intra-rater reliability was moderate to high and inter-rater reliability of the device was excellent, with intraclass correlation coefficients ranging from 0.527–0.851 and 0.834–0.953, respectively, for all positions. CONCLUSIONS: The barre-mounted stabilizing device shows promise in mitigating tester strength or fatigue in assessing muscle performance of dancers. Initial assessment of the device suggests further study may be indicated to improve generalizability to applications of larger-scale muscle performance screening and assessment in dancers or other athletic populations who engage in movements that require extensive hip range of motion and multi-joint stability. CLINICAL RELEVANCE: Using a portable, barre-mounted stabilizing device in assessing multi-joint lower extremity muscle performance in dancers improves consistency of testing results. Application of this testing device into wider scale screenings could assist in developing normative data for a population that is lacking

    Closing the loop in exergaming - Health benefits of biocybernetic adaptation in senior adults

    Get PDF
    Exergames help senior players to get physically active by promoting fun and enjoyment while exercising. However, most exergames are not designed to produce recommended levels of exercise that elicit adequate physical responses for optimal training in the aged population. In this project, we developed physiological computing technologies to overcome this issue by making real-time adaptations in a custom exergame based on recommendations for targeted heart rate (HR) levels. This biocybernetic adaptation was evaluated against conventional cardiorespiratory training in a group of active senior adults through a floor-projected exergame and a smartwatch to record HR data. Results showed that the physiologically-augmented exergame leads players to exert around 40% more time in the recommended HR levels, compared to the conventional training, avoiding over exercising and maintaining good enjoyment levels. Finally, we made available our biocybernetic adaptation software tool to enable the creation of physiological adaptive videogames, permitting the replication of our study.info:eu-repo/semantics/publishedVersio

    Measurement of νˉμ\bar{\nu}_{\mu} and νμ\nu_{\mu} charged current inclusive cross sections and their ratio with the T2K off-axis near detector

    Get PDF
    We report a measurement of cross section σ(νμ+nucleusμ+X)\sigma(\nu_{\mu}+{\rm nucleus}\rightarrow\mu^{-}+X) and the first measurements of the cross section σ(νˉμ+nucleusμ++X)\sigma(\bar{\nu}_{\mu}+{\rm nucleus}\rightarrow\mu^{+}+X) and their ratio R(σ(νˉ)σ(ν))R(\frac{\sigma(\bar \nu)}{\sigma(\nu)}) at (anti-)neutrino energies below 1.5 GeV. We determine the single momentum bin cross section measurements, averaged over the T2K νˉ/ν\bar{\nu}/\nu-flux, for the detector target material (mainly Carbon, Oxygen, Hydrogen and Copper) with phase space restricted laboratory frame kinematics of θμ\theta_{\mu}500 MeV/c. The results are σ(νˉ)=(0.900±0.029(stat.)±0.088(syst.))×1039\sigma(\bar{\nu})=\left( 0.900\pm0.029{\rm (stat.)}\pm0.088{\rm (syst.)}\right)\times10^{-39} and $\sigma(\nu)=\left( 2.41\ \pm0.022{\rm{(stat.)}}\pm0.231{\rm (syst.)}\ \right)\times10^{-39}inunitsofcm in units of cm^{2}/nucleonand/nucleon and R\left(\frac{\sigma(\bar{\nu})}{\sigma(\nu)}\right)= 0.373\pm0.012{\rm (stat.)}\pm0.015{\rm (syst.)}$.Comment: 18 pages, 8 figure

    Measurements of neutrino oscillation in appearance and disappearance channels by the T2K experiment with 6.6 x 10(20) protons on target

    Get PDF
    111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee comments111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee comments111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee commentsWe thank the J-PARC staff for superb accelerator performance and the CERN NA61/SHINE Collaboration for providing valuable particle production data. We acknowledge the support of MEXT, Japan; NSERC, NRC, and CFI, Canada; CEA and CNRS/IN2P3, France; DFG, Germany; INFN, Italy; National Science Centre (NCN), Poland; RSF, RFBR and MES, Russia; MINECO and ERDF funds, Spain; SNSF and SER, Switzerland; STFC, UK; and the U. S. Deparment of Energy, USA. We also thank CERN for the UA1/NOMAD magnet, DESY for the HERA-B magnet mover system, NII for SINET4, the WestGrid and SciNet consortia in Compute Canada, GridPP, UK, and the Emerald High Performance Computing facility in the Centre for Innovation, UK. In addition, participation of individual researchers and institutions has been further supported by funds from ERC (FP7), EU; JSPS, Japan; Royal Society, UK; and DOE Early Career program, USA

    Measurement of the electron neutrino charged-current interaction rate on water with the T2K ND280 pi(0) detector

    Get PDF
    10 pages, 6 figures, Submitted to PRDhttp://journals.aps.org/prd/abstract/10.1103/PhysRevD.91.112010© 2015 American Physical Society11 pages, 6 figures, as accepted to PRD11 pages, 6 figures, as accepted to PRD11 pages, 6 figures, as accepted to PR

    Search for short baseline nu(e) disappearance with the T2K near detector

    Get PDF
    8 pages, 6 figures, submitted to PRD rapid communication8 pages, 6 figures, submitted to PRD rapid communicationWe thank the J-PARC staff for superb accelerator performance and the CERN NA61 collaboration for providing valuable particle production data. We acknowledge the support of MEXT, Japan; NSERC, NRC and CFI, Canada; Commissariat `a l’Energie Atomique and Centre National de la Recherche Scientifique–Institut National de Physique Nucle´aire et de Physique des Particules, France; DFG, Germany; INFN, Italy; National Science Centre (NCN), Poland; Russian Science Foundation, RFBR and Ministry of Education and Science, Russia; MINECO and European Regional Development Fund, Spain; Swiss National Science Foundation and State Secretariat for Education, Research and Innovation, Switzerland; STFC, UK; and DOE, USA. We also thank CERN for the UA1/NOMAD magnet, DESY for the HERA-B magnet mover system, NII for SINET4, the WestGrid and SciNet consortia in Compute Canada, GridPP, UK. In addition participation of individual researchers and institutions has been further supported by funds from ERC (FP7), EU; JSPS, Japan; Royal Society, UK; DOE Early Career program, USA

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT

    Search for direct production of charginos and neutralinos in events with three leptons and missing transverse momentum in √s = 7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for the direct production of charginos and neutralinos in final states with three electrons or muons and missing transverse momentum is presented. The analysis is based on 4.7 fb−1 of proton–proton collision data delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in three signal regions that are either depleted or enriched in Z-boson decays. Upper limits at 95% confidence level are set in R-parity conserving phenomenological minimal supersymmetric models and in simplified models, significantly extending previous results
    corecore